Pvcheck – HT instruments PVCHECK User Manual

Page 40

Advertising
background image

PVCHECK

EN - 38

6.3.4.1. Anomalous

situations when performing IVCK tests

1. In case the instrument detects a voltage higher than

1000V at terminals P-N, P-E and N-E, it does not carry
out the test, gives out a long sound and displays the
message “Vin > 1000”.

15/05/12 15:34:26

M o d u l e :

S U N P W R 3 1 8

V d c

:

0 . 0 V

I r r

:

0 W / m 2

T c

:

A u t o ° C

V o c , I s c :

R i ( 1 0 0 0 V )

- - -

M

R p e ( C a l )

- - -

Vin > 1000

Selection

I V C K

2. In case the instrument detects a voltage lower than 15V

at terminals P and N, it does not carry out the test, gives
out a long sound and displays the message “Low
voltage”.

15/05/12 15:34:26

M o d u l e :

S U N P W R 3 1 8

V d c

:

0 . 0 V

I r r

:

0 W / m 2

T c :

A u t o

° C

V o c , I s c :

R i ( 1 0 0 0 V )

- - -

M

R p e ( C a l )

- - -

Low voltage

Selection

I V C K

3. In case the instrument detects a voltage higher than > 5V

at terminals E and C, it does not carry out the test, gives
out a long sound and displays the message “Voltage >
Lim”.

15/05/12 15:34:26

M o d u l e :

S U N P W R 3 1 8

V d c

:

0 . 0 V

I r r

:

0 W / m 2

T c

:

A u t o ° C

V o c , I s c :

R i ( 1 0 0 0 V )

- - -

M

R p e ( C a l )

- - -

Voltage > Limit

Selection

I V C K

4. In case the instrument detects an Isc current higher than

10A, it does not carry out the test, gives out a long sound
and displays the message “Isc current too high”.

15/05/12 15:34:26

M o d u l e :

S U N P W R 3 1 8

V d c

:

0 . 0 V

I r r

:

0 W / m 2

T c :

A u t o

° C

V o c , I s c :

R i ( 1 0 0 0 V )

- - -

M

R p e ( C a l )

- - -

Isc current too high

Selection

I V C K

Advertising