7.3.2.1. Accessing the data saved in the memory – Numeric display
1. Select a line corresponding to a saved result and press

ENTER.

2. Select “Open” and press ENTER to open the section

where measurement results are displayed as:
 Numeric screens of measured parameters under

standard (STC) conditions and under operating
(OPC) conditions for IVCK tests

 Numeric screens of measured parameters when

measuring insulation (M

) and continuity (LOW).

15/05/12 15:34:26

MEM Comments

001

PV PLANT 1

002*

PV PLANT 2

O p e n

R e c a l l

D e l e t e

Selection

MEM-IVCK

3. For IVCK test, there are the values of the following

parameters:

 The module being used
 The value of irradiance
 The value of temperature of the module
 The average values of Voc and Isc under OPC

conditions

 The values of Voc and Isc measured under OPC

conditions

 The values of Voc and Isc calculated under STC and

the relevant partial results obtained by comparison with
the nominal values.

15/05/12 15:34:26

M o d u l e : S U N P W R 2 1 0

I r r

9 0 3 W / m 2

T c ( A U T O )

5 7 ° C

V o c A v g @ O P C

- - -

V

I s c A v g @ O P C

- - -

A

V o c @ O P C

6 4 7

V

I s c @ O P C

5 . 3 5

A

V o c @ S T C

7 8 7

V O K

I s c @ S T C

5 . 7 2

A O K

Outcome: OK

Selection

I V C K

4. For M

 test in FIELD mode there are the values of the

following parameters:

 Set rated test voltage
 Minimum threshold set on insulation measurement
 The type of mode·selected
 The real value of the applied test voltage
 The insulation value of positive pole Ri (+)
 The insulation value of positive pole Ri (-)


15/05/12 15:34:26

I n s . T e s t

:

1 0 0 0

V

R i m i n

:

1 . 0

M

M o d e :

F i e l d

V t e s t 1 0 6 5

1 0 6 4

V

R i ( + )

> 1 0 0

M

R i ( - )

> 1 0 0

M

R p

7 2

M

Outcome: OK

Selection

M

5. For M

 test in TIMER mode there are the values of the

following parameters:

 Set rated test voltage
 Minimum threshold set on insulation measurement
 The type of selected mode
 The real value of the applied test voltage
 The Ri(+) minimum value of insulation resistance of

the PV module/string (or of other metal masses)
being tested, continuously measured during the
whole duration of measurement.

 The set measuring time


15/05/12 15:34:26

I n s . T e s t

:

1 0 0 0

V

R i m i n

:

1 . 0

M

M o d e :

T i m e r

V t e s t

1 0 2 0

V

R i ( + ) m i n

> 2 0 0

M

Test time: 10s

Oucome: OK

Selection

M