Caution, Pvcheck – HT instruments PVCHECK User Manual

Page 35

Advertising
background image

PVCHECK

EN - 33

6.3.3. Carrying out an IVCK quick test and measuring irradiance

CAUTION

 The maximum voltage between inputs P, N, E and C is 1000VDC. Do not

measure voltages exceeding the limits given in this manual.

 Do not perform test on PV modules or strings connected to the DC/AC

converter

The maximum current which can be measured by the instrument is 10A.

Before carrying out the measures of IVCK and Insulation in "STRING"
mode, always ensure that the instrument is connected to ONE STRING
and not more strings in parallel to avoid possible damage of it

1. Switch on the instrument by pressing the ON/OFF key.
2. Irradiance measurement is carried out in one of the following modes:

 Measurement by reference cell directly connected to PVCHECK
 Measurement by reference cell connected to a connected SOLAR-02 unit RF with

PVCHECK

3. Check that the settings of remote unit SOLAR-02 are consistent with the type of

measurement to be carried out (see § 5.1.4).

4. Check the minimum irradiance value set (see § 5.1.5).
5. Position the cursor onto IVCK by using the arrow keys

(

,) and confirm with ENTER. The display shows the

screen to the side: The meaning of the parameters is the
following:

Module  type of module being tested
Vdc  value of output voltage from module/string

measured in real time

Irr  value of irradiation measured in real time
Tc  value of module temperature (see § 5.5.1)
Voc, Isc  section with display of result OK/NO of

Voc and Isc measurement

Ri()  the value in brackets may be NO/selected test

voltage (see § 5.5.1). The value of Ri indicates the
insulation resistance

Rpe()  the value in brackets may be NO, Cal or

NoCal (see § 5.5.1). The value of Rpe indicates the
result of the continuity test.

15/05/12 15:34:26

M o d u l e :

S U N P W R 3 1 8

V d c

:

0 . 0 V

I r r

:

0 W / m 2

T c :

A u t o

° C

V o c , I s c :

R i ( 1 0 0 0 V )

- - -

M

R p e ( C a l )

- - -

Selection

I V C K

6. Press the ENTER key, select “Settings” and confirm again with ENTER. Set the

instrument as indicated in § 5.5.1

7. If necessary, press the ENTER key, select “Average Reset” and confirm again with

ENTER. Carry out this operation as indicated in § 6.3.4

8. If necessary, press the ENTER key, select “Cable calibration” and confirm again with

ENTER. Carry out this operation as indicated in § 6.5.2

9. Mount the rod onto the disc of the optional accessory M304 and keep it in touch with

the module’s surface. Make sure that the shadow cast by the rod onto the disc
falls within the “limit internal circle” on the disc itself (see Fig. 7)
. If this is not the
case, the incidence angle between the sun rays and the module surface is too high and,
therefore, the measurements carried out by the instrument CANNOT be considered
reliable. Repeat the same operations at another daytime.

10. Fasten the bracket to the module by using the supplied set of screws and mount the

reference cell on it, if possible with output terminals facing downwards. Rotate the

Advertising