Technical specifications – HT instruments PVCHECK User Manual

Page 61

Advertising
background image

PVCHECK

EN - 59

10. TECHNICAL SPECIFICATIONS

10.1. TECHNICAL SPECIFICATIONS FOR PV INSTALLATION EFFICIENCY

Accuracy is indicated as

[%reading + (no. of digits) * resolution] at 23°C ± 5°C, <80%HR

DC voltage

Range [V]

Resolution [V]

Accuracy

5.0

 199.9

0.1

(1.0rdg + 2dgt)

200.0

 999.9

0.5

DC current (by means of external clamp transducer)

Range [mV]

Resolution [mV]

Accuracy

-1100

 -5

0.1

(0.5rdg + 0.6mV)

5

 1100

The value of current is ALWAYS displayed with a positive sign: the value of current transduced in a voltage lower than 5mV is zeroed.

FS DC clamp [A]

Resolution [A]

Minimum read value [A]

1< FS

 10

0.001 0.05

10< FS

 100

0.01 0.5

100< FS

 1000

0.1 5

DC power (Vmis > 150V)

Clamp FS [A]

Range [W]

Resolution [W]

Accuracy

1< FS

 10

0.000k

 9.999k

0.001k

(1.5rdg + 3dgt)

(Imis < 10%FS)

(1.5rdg)

(Imis

 10%FS)

10< FS

 100

0.00k

 99.99k

0.01k

100< FS

 1000

0.0k

 999.9k

0.1k

Vmis = voltage at which power is measured; Imis = measured current

Irradiance (with HT304N reference cell)

Range [mV]

Resolution [mV]

Accuracy

1

 40.0

0.02

(1.0rdg + 0.1mV)

Temperature (with probe type PT300N)

Range [°C]

Resolution [°C]

Accuracy

-20.0

 100.0

0.1

(1.0rdg + 1°C)

Advertising