10.2. TECHNICAL SPECIFICATIONS OF THE IVCK FUNCTION

DC Voltage @ OPC

Range [V]

Resolution [V]

Accuracy

5.0

 199.9

0.1

(1.0rdg + 2dgt)

200

 999

0.5

Minimum VPN voltage to start the test: 15V

DC Current @ OPC

Range [A]

Resolution [A]

Accuracy

0.10

 10.00

0.01

(1.0rdg + 2dgt)

DC Voltage @ STC

Range [V]

Resolution [V]

Accuracy

5.0

 199.9

0.1

(4.0rdg + 2dgt)

200

 999

1

DC Current @ STC

Range [A]

Resolution [A]

Accuracy

0.10

 10.00

0.01

(4.0rdg + 2dgt)

Irradiance (with HT304N reference cell)

Range [mV]

Resolution [mV]

Accuracy

1

 40.0

0.02

(1.0rdg + 0.1mV)

Temperature (with probe type PT300N)

Range [°C]

Resolution [°C]

Accuracy

-20.0

 100.0

0.1

(1.0rdg + 1°C)

10.3. TECHNICAL SPECIFICATIONS FOR ELECTRICAL SAFETY

Continuity of protective conductors (LOW

)

Range [

] Resolution

[

]

Accuracy

0.00

 1.99

0.01

(2.0rdg + 2dgt)

2.0

 19.9

0.1

20

 199

1

Test current >200mA DC up to 5

 (cables included), resolution 1mA, accuracy (5.0%reading + 5digits)

Open-circuit voltage

4 < V

0

< 10V

Insulation resistance (M

) – Mode TIMER

Test voltage [V]

Range [M

] Resolution

[M

]

Accuracy

250, 500, 1000

0.01

 1.99

0.01

(5.0rdg + 5dgt)

2.0

 19.9

0.1

20

 199

1

Open voltage

<1.25 x nominal test voltage

Short circuit current

< 15mA (peak) for each test voltage

Generated voltage

resolution 1V, accuracy

(5.0%reading + 5digits) @ Rmis> 0.5% FS

Rated current measured

> 1mA with 1k

 @ Vnom

Insulation resistance (M

) – Mode FIELD (*), STRING (**)

Test voltage [V]

Range [M

] Resolution

[M

]

Accuracy (***)

250, 500, 1000

0.1

 1.9

0.1

(20.0rdg + 5dgt)

2

 99

1

(*) For FIELD mode

if VPN >1V the minimum voltage VEP and VEN for the calculation of Ri(+) and Ri(-) is 1V

(**) For STRING mode

minimum VPN voltage to start the test: 15V

Open voltage

<1.25 x nominal test voltage

Short circuit current

< 15mA (peak) for each test voltage

Generated voltage

resolution 1V, accuracy

(5.0%reading + 5digits) @ Rmis> 0.5% FS

Rated current measured

> 1mA with 1k

 @ Vnom

(***) For FIELD mode:

add 5 dgts to the accuracy if

100

,

min

,

max

R

R

R

R

Advertising