 4. SPECIFICATION

Measurement Specification

Function

Range

Rated Voltage

(AC)

Test

Current

Accuracy

LOOP

PSC

Function

Uc

20Ω

L-PE :

+10%

230V

50Hz

-15%

3A

15mA

15mA

15mA

3A

max15mA

5mA only at

I⊿n=10mA

± (3%rdg+8dgt)

± (3%rdg+8dgt)

At L-L measurement:

± (3%rdg+12dgt)

± (3%rdg+8dgt)

PSC accuracy is a

derived from

measured loop

impedance

specification.

200Ω

2000Ω

200A

2000A

20kA

L-PE :

+10%

230V

50Hz

-15%

L-L :

+10%

400V

50Hz

-15%

L-PE :

+10%

230V

50Hz

-15%

L-L :

+10%

400V

50Hz

-15%

L-PE :

+10%

230V

50Hz

-15%

Range

100V

Rated Voltage

(AC)

L-PE :

+10%

230V

50Hz

-15%

Test

Current

Accuracy

+5%∼+15%

± 8dgt