3.4 Test Range (Function)

Model 6050 performs four functions.

1. LOOP.....Loop impedance tester

2. RCD.......RCD tester

3. Uc..........Contact voltage tester

4. PSC.......Prospective short circuit current tester

3.5 Applied Standards

Instrument operation: IEC/EN61557-1,3,6,10

Safety:       IEC/EN61010-1 CATⅢ(300V)-instrument

           IEC/EN61010-031 CATⅢ(600V)-test lead

Protection degree:  IEC60529(IP54)

3.6 Features

Model 6050 has the following features:

● Wiring check

Three LEDs indicate if the wiring of the circuit

under test is correct.

● Over temperature

protection

Detects overheating of the internal resistor and

of the current control MOS FET displaying a

warning symbol (

) and automatically halting

further measurements.

● Phase angle

  selector

RCD test can be selected from either the

positive (0°

) or from the negative (180°) half-

cycle of voltage. At both polarity, test minimum

(best) and maximum (worst) trip times.

● Auto data hold

Measured result is being held until any switch

other than MEM switch is pressed. Instrument

is back to voltage measurement mode when

applying voltage again during data hold

function is operated.