Accessori, Accessories – Airedale EcoChill 6kW - 46kW User Manual

Page 11

Advertising
background image

11

EcoChill Installation Manual 7481930_v1.6.0_08_2013

ECL-ECLH 020-202

EN

VT ANTI-VIBRATION MOUNTS

Set of anti-vibration mounts.

MODU-485A 4

Interface RS-485 for supervisory systems with MODBUS

protocol.

DCPX 4

Fan speed controller which allows correct operation

in cooling mode between external air temperatures of

+20°C and -10°C, in heat pump mode, in the summer

for production of domestic hot water, up to +42°C

(refer to the operating limits diagram).

In versions with desuperheater fitted as standard.

DRE 5

Electronic soft starter (reduces approximately 30%

in single circuits, 26% in dual circuits, 22% in three

circuits).

RA 7

Buffer tank electric heater (in versions A|Q). Provides

freeze protection of the buffer tank in winter off

periods.

KR 6 7

Evaporator electric heater

Plate heat exchanger electric heater. Provides freeze

protection of the evaporator in winter off periods.

AERWEB300

Allows the remote control of a chiller using a normal

PC connected via ethernet through a normal browser.

Available in 4 models:

AERWEB300-6: Web server for monitor and control of

a maximum of 6 units on a network RS485;

AERWEB300-18: Web server for monitor and control of

a maximum of 18 units on a network RS485;

AERWEB300-6G: Web server for monitor and control

of a maximum of 6 units on a network RS485 with

modem GPRS integrated;

AERWEB300-18G: Web server for monitor and control

of a maximum of 18 units on a network RS485 with

modem GPRS integrated.

BDX

Condensate drain pan.

KR B3 7

Base electric heater kit: avoids ice forming in the base.

MULTICONTROL

Allows the simultaneous control of multiple chillers

or heat pump units (up to 4) installed in a common

system, fitted with our MODU-CONTROL controller.

For a more complete function the following accessories

are available:

SPLW

System water sensor. In most cases the use of the sen-

sors supplied loose with each chiller/heat pump unit is

sufficient. In the case of common flow / return header

installation this sensor can be used to control the com-

mon water temperature of the chillers connected to

the header or just for reading values.

SDHW

Domestic hot water sensor. To be used with a storage

tank for the control of water temperature produced.

VMF-ACS

Electrical panel for enabling / complete control of a

domestic hot water tank:

1.

3 way valve control

2.

Anti-legionella

3.

Temperature sensor

4.

Immersion heater of:

3 kW single |three phase

6 kW three phase

8 kW three phase

VMF-E5B|N

Recess mounted panel or white or black colour with

back-lit LCD graphical display and capacitive keypad.

Allows enabling/centralised control of:

1.

A complete hydronic system comprising 1 master

and maximum of 5 slave fan coil units

2.

ChillerPump (INTERFACE RS 485 FROM MODU-

485A REQUIRED ACCESSORY)

3.

Circulating pumps: maximum configuration of 12

zone circulators

4.

Boiler: control of boiler enable for the produc-

tion of hot water

5.

Heat recovery units: maximum of 3 enables for

heat recovery units programmable by time-clock

and/or air quality sensor VMF-VOC, domestic hot

water module

6.

Complete control of domestic hot water produc-

tion (ACCESSORY VMF-ACS see above).

ECL

020

ECL

025

ECL

030

ECL

040

ECL

050

ECL

070

ECL

080

ECL

090

ECL

102

ECL

152

ECL

202

PR3

(°) - H - C

MODU-485A

4

ALL

AERWEB300-6

ALL

AERWEB300-18

ALL

AERWEB300-6G

ALL

AERWEB300-18G

ALL

DRE

5

(°) - H - C

-

-

-

-

5

5

5

5

5x2 5x2 5X2

MULTICONTROL

ALL

SPLW

SDHW

DCPX

4

(°) - C

50

50

50

50

50

50

50

50

52

52

52

H

51

51

51

51

51

51

51

51

53

53

53

VT

(°) - H - HP - C

9

9

9

9

9

9

9

9

15

15

15

A

9

9

9

9

15

15

15

15

15

15

15

RA

A

BDX

(°) / P

5

5

5

5

5

5

5

5

-

-

-

A

5

5

5

5

6

6

6

6

-

-

-

KR

6

(°) / P

2

2

2

2

2

2

2

2

2

2

2

A

-

-

-

-

2

2

2

2

2

2

2

KRB

7

-

-

-

-

-

-

-

-

3

3

3

VMF-E5B|N

4

ALL

VMF-ACS3KM

4

230V/1

VMF-ACS3KTN

4

400V/3N

VMF-ACS6KTN

4

400V/3N

VMF-ACS8KTN

4

400V/3N

4 Accessories MODU-485A |DCPX are required

for the control and production of DHW.

5 Only available with power supply 400V/3N

Factory fitted only.

6 Accessory not available for versions ECL

020…040°A | HA.

7 Factory fitted only.

x2 Indicates the quantity to order.

6.

ACCESSORIES

Advertising