CTION

Standards applied in the DESIGN and

MANUFACTURE of the unit:

SAFETY

1.

Machinery directive

2006/42/CE

2.

Low voltage directive

LVD 2006/95/CE

3.

Electromagnetic compatibility

directive EMC 2004/108/CE

4.

Pressure vessel directive

PED 97/23/CE, EN 378,

5.

UNI12735, UNI14276

ELECTRICAL

1.

IEC EN 60335-2-40,

2.

IEC EN 61000-6-1/2/3/4

ACOUSTICAL

1.

ISO DIS 9614/2

(intensity method)

PROTECTIVE RATING

IP24

CERTIFICATION

EUROVENT

UNI EN 14511:2011

REFRIGERANT

This unit contains fluoride gases with

greenhouse effect covered by the Kyoto

Protocol. Maintenance and disposal

must only be carried out by qualified

staff, in accordance with local regula-

tions

WARNING

1.

The refrigerant circuit is under

pressure. Additionally, high tem-

peratures can be generated. The

unit can only be worked on by a

TAS technical assistance operative

or a qualified technician. Inter-

ventions on the refrigerant circuit

can only be carried out by a quali-

fied refrigeration technician.

2.

GAS R410A

The units are delivered with their

operating charges of refriger-

ant R410A. This is a refrigerant

without chlorine which does not

damage the ozone layer. R410A is

not flammable. All maintenance

procedures must be carried out

by a qualified technician with the

appropriate safety equipment.

3.

Danger of electrical shock!

Completely disconnect the unit

from the power supply before

starting procedures.

19. GENERAL INSTRUCTIONS FOR THE INSTALLER

The AIREDALE ECL units are manufactured in accord-

ance with recognised technical and safety standards.

They are designed for air conditioning and production

of domestic hot water (DHW) and must be used in a

manner compatible with their performance character-

istics. All contractual and extra-contractual liabilities

causing damage to persons, animals or objects or

through errors of installation, control or maintenance

or from improper use are excluded by the Company.

Any uses not expressly indicated in this manual are not

permitted.

19.1. CONSERVATION OF DOCUMENTATION

1.

Submit the manual with all supplementary

documentation to the system user who will be

responsible for the conservation of documents

so that they can be available when needed.

2.

Read this manual fully: all works must be carried

out by qualified personnel, in accordance with

any applicable current local regulations.

3.

The unit must be installed in a manner to render

possible maintenance and/or repair operations.

4.

The equipment warranty does not cover any

costs associated with lifting or access equipment

necessary for warranty procedures.

5.

Do not modify or tamper with the equipment

as this could result in accidents for which the

manufacturer will not be held responsible. The

warranty will be voided if the above mentioned

warnings are not respected.

19.2. SAFETY INSTRUCTIONS AND INSTALLA-

TION STANDARDS

1.

The equipment must be installed by a competent

and qualified technician, in compliance with the

applicable national legislation of the country of

destination. AIREDALE assumes no responsibil-

ity for any losses incurred by not observing these

instructions.

2.

Before commencing any works it is necessary

to CAREFULLY READ THE INSTRUCTIONS AND

MINIMISE ANY RISKS BY TAKING APPROPRIATE

SAFETY PRECAUTIONS. All relevant personnel

must be made aware of the procedures and

possible risks that may arise at the time of instal-

lation of the unit.