Start, Pause, Stop – Radio Modes

ORION Migratable and Fixed Network endpoints are programmed at the factory to begin sending meter readings when the

register senses flow through the meter As a result, the endpoints can be installed on meters without having to manually start

the endpoint When water usage is registered on the meter, the endpoint sends a signal every 5…6 seconds The following

statuses can display in the Radio field on the ORION Migratable IR Programming screen

Stopped

The endpoint is not transmitting A stopped endpoint must be reprogrammed to begin transmitting

again Stored historical endpoint interval data (profile data) is cleared when the endpoint is restarted

Paused

Endpoint is in non-transmission mode temporarily until a unit of water or gas is registered Commonly

used for seasonal customer accounts

On-Mobile Mode An ORION Migratable or Fixed Network endpoint begins in mobile mode and continues to transmit in

mobile mode until and unless communication is established with an ORION Fixed Network gateway

transceiver An endpoint in mobile mode sends a message requesting gateway assignment once

every hour If a gateway responds with an assignment using two-way communication, the endpoint

automatically switches to On-Fixed Mode Fixed mode transmissions cannot be received by the

handheld transceiver

Discovery Mode For troubleshooting only To be used under the direction of Badger Meter Technical Support
On-Fixed Mode

An endpoint in On-Fixed Mode is assigned to an ORION Fixed Network gateway transceiver for data

collection It reverts to On-Mobile Mode if the endpoint fails to receive a response from a gateway

for four consecutive days Once communication is re-established with the gateway, the endpoint

automatically transitions to On-Fixed Mode

The Stop button suspends data profiling and stops an endpoint from sending a signal,

regardless of the usage registered from the meter Align the optical head on the IR cable

with the endpoint IR LED port and tap Stop Tap Start to turn the endpoint on again The

endpoint history (profile data) is cleared when the endpoint is restarted See

Profile data

Warning

below

The Pause button temporarily stops the radio signal Align the optical head on the IR

cable with the endpoint IR LED port and tap Pause The endpoint begins transmitting

again when a unit of water is registered from the meter

Figure 17: Radio modes

The Start button is used to start an endpoint after it is Stopped or before usage is registered Align the optical head on the IR

cable with the endpoint IR LED port and tap Start

NOTE:

N

Stopped radios must be restarted using the Start function and will not automatically restart when usage is registered

from the meter When used with an RTR, the odometer value must also be programmed to reflect the current

registration reading When used with an ADE, the odometer value is automatically updated within the hour

NOTE:

N

An ORION Migratable or Fixed Network endpoint connected to an ADE (or approved competitive three-wire encoder)

does not require programming to clear a tamper After the wires have been repaired, the endpoint is automatically

updated to reflect the register odometer value in the first hour after the wires have been repaired

Figure 18: Stop endpoint warning

Profile Data Warning

The warning screen shown here is displayed when you

tap Stop
Stopping an endpoint suspends data profiling Restarting

clears all historical interval data (profile data) and places fixed

mode endpoints into mobile mode Endpoints in mobile

mode may not revert to fixed mode for up to 48 hours

NOTE:

N

It is not necessary to tap Stop / Start before and