High resolution (hr) e lcd extended status – Badger Meter ORION Classic (CE) User Manual

Page 26

Advertising
background image

High Resolution (HR) E LCD Extended Status

Figure 28: Extended Status - HR-E lcd

The status indicators described below apply for an ORION Migratable (or Fixed Network in mobile mode) endpoint when

connected to an HR-E LCD encoder

Status Indicator

Description

EP Prog

Endpoint is reporting that it has been reprogrammed via IR

EP Tamper

Endpoint is reporting a tamper condition This condition occurs when the wire between the

encoder and the endpoint is cut or shorted, or the encoder is not connected

Mobile Mode

Endpoint is communicating in mobile transmission mode

EP Low Battery

Endpoint is reporting a low battery condition

Encoder Error

Encoder is reporting a device error to the endpoint

Removal

Encoder is reporting an encoder removal condition to the endpoint

Temp

Encoder is reporting to the endpoint that it senses temperatures outside the specified range

ENC End of Life

Encoder is reporting to the endpoint that the encoder battery life indicator has been activated

No Usage

Encoder is reporting a no usage condition to the endpoint

Reverse Flow

Encoder is reporting a reverse flow condition to the endpoint

Leak

Encoder is reporting a potential leak condition to the endpoint

ENC Prog

Encoder is reporting to the endpoint that the encoder has been reprogrammed via IR

Mag Tamper

Encoder is reporting a magnetic tamper condition to the endpoint

Encoder Information

Description

Size & Type

The size and type of the meter for which the encoder was programmed

Units

The units of measure as defined by the encoder: cubic meters, cubic feet, gallons, imperial gallons

or liters

Encoder

The encoder protocol

Dials

Encoder dial resolution (8) as reported from the encoder

Reverse Flow Total

The total reverse flow units measured by the encoder

NOTE:

N

Refer to the HR-E lcd Encoder Installation and Programming manual, available at

www.badgermeter.com

, for a detailed

list of encoder status indicators