RTR Extended Status

Figure 26: Extended Status- RTR

The status indicators described below apply for an ORION Migratable (or Fixed Network in mobile mode) endpoint when

connected to an RTR

Status Indicator

Description

Mobile Mode

Endpoint is communicating in mobile transmission mode

IR Programmed

Endpoint has been reprogrammed via IR

Low Battery

Endpoint is reporting a low battery condition

Tamper

Endpoint is reporting a tamper condition This condition occurs when the wire between the register

and the endpoint is cut or shorted, or the RTR is not connected See

"" on page 19

for instructions

on clearing the tamper

No Usage

Endpoint is reporting a no usage condition This condition occurs when there is no water flow

registered over a 30-day time frame

Leak

Endpoint is reporting a potential leak condition when there is continuous usage over a 24-hour time

period without a 1-hour period of non-usage

Encoder Information Description

Size & Type

The size and type of the meter for which the RTR was programmed Tap the button to change the

size and type See

"IR Programming Meter Size, Type and Units of Measure (RTR, AdE)" on page 28

for

more information

Units

The units of measure as defined by the RTR: cubic meters, cubic feet, gallons, imperial gallons or

liters Tap the button to change the units See

"IR Programming Meter Size, Type and Units of Measure

(RTR, AdE)" on page 28

for more information