Ir programming an orion classic gas endpoint – Badger Meter ORION Classic (CE) User Manual

Page 38

Advertising
background image

IR Programming an ORION Classic Gas Endpoint

NOTE:

N

Before beginning, make sure the IR programming cable is connected and the COM port is set correctly See

"Hardware

Settings" on page 63

for additional information

1 From the ORION Endpoint Utility menu, tap ORION IR Programming
2 Align the optical head of the IR cable with the gas endpoint IR LED port Then tap Read

Result: The Select gas drive circle screen is displayed automatically.

Figure 53: IR programming screen with Read

Figure 54: Select gas drive circle screen

3 To change the pressure factor, tap in the Pressure

field Use the keypad to change the pressure factor,

if necessary

4 Select the Drive Circle for the gas endpoint

Use the selections in the top half of the screen

to filter the list on the bottom by choosing

Integral or Remote, and choosing the Units,

Dials and Res (resolution)

Or just scroll through the list to find the drive

circle for the endpoint

5 Tap the Select button to store the drive circle

Figure 55: gas pressure factor

6. Result: The IR Programming screen is displayed with the

selected drive circle displayed.

Figure 56: gas drive circle

ORION IR PROgRAMMINg

Page 38

April 2014

ORION® Endpoint Utility for Trimble® Ranger 3

Advertising
This manual is related to the following products: