IR Programming an ORION Migratable Endpoint (RTR)

When used with an RTR encoder, you must program and set the endpoint odometer value following a tamper repair

Reading the Odometer

To install an ORION Migratable endpoint on an active meter with usage on the RTR, use the following information to ensure

that the value in the endpoint matches the current odometer value on the RTR once the endpoint is connected to the RTR

When programming ORION endpoints, enter the value of the

six moveable odometer wheels plus the sweep hand for all

meter types (gallons, cubic feet, etc ) and all meter models
In Figure 19, the odometer value in the moveable dials (both

white and black digits) is "000001 "
The sweep hand is pointing between the "6" and the “7" but

because the sweep hand has not yet hit the "7", use "6" as the

value for the last digit of the meter reading Therefore, in this

example, the value to be entered into the ORION endpoint

Reading field would be "16" or "0000016 " (The leading zeros

are not required )

Figure 19: Odometer value

When programming an ORION endpoint connected to an

E-Series meter with an RTR protocol, program the seven most

significant (left-most) digits shown on the meter display

NOTE:

N

For instructions on programming a gas endpoint,

see

"IR Programming an ORION Migratable gas

Endpoint" on page 32

Figure 20: E-Series meter display

1 Align the optical head of the IR cable with the

endpoint IR LED port and tap Read on the IR

Programming screen

2 Double-tap the reading in the Reading field

Result: The current reading in the field is highlighted

(Figure 21).

Figure 21: RTR Reading field