High Resolution (HR) E-Series Extended Status

Figure 29: Extended Status - HR E-Series

The status indicators described below apply for an ORION Migratable (or Fixed Network in mobile mode) endpoint when

connected to an HR E-Series meter

Status Indicator

Description

EP Prog

Endpoint is reporting that it has been reprogrammed via IR

EP Tamper

Endpoint is reporting a tamper condition This condition occurs when the wire between the

E-Series meter and the endpoint is cut or shorted, or the encoder is not connected

Mobile Mode

Endpoint is communicating in mobile transmission mode

EP Low Battery

Endpoint is reporting a low battery condition

Encoder Error

E-Series meter is reporting a device error to the endpoint

Empty Pipe

E-Series meter is reporting a no flow condition in the pipe

Low Temp

E-Series meter indicates the low temperature limits have been exceeded

ENC End of Life

E-Series meter is reporting to the endpoint that the encoder battery life indicator has been

activated

No Usage

E-Series meter is reporting a no usage condition to the endpoint

Reverse Flow

E-Series meter is reporting a reverse flow condition to the endpoint

Leak

E-Series meter is reporting a potential leak condition to the endpoint

Sensor Error

Endpoint is reporting a sensor error or meter alarm other than empty pipe or low temp

Encoder Information

Description

Size & Type

The size and type for which the E-Series meter was programmed

Units

The units of measure as defined by the E-Series meter: cubic meters, cubic feet, gallons,

imperial gallons or liters

Encoder

The encoder protocol

Dials

Encoder dial resolution (8) as reported from the E-Series meter

Reverse Flow Total

The total reverse flow units measured by the E-Series meter

NOTE:

N

Refer to the E-Series Installation and Programming manuals, available at

www.badgermeter.com

, for a detailed list of

encoder status indicators

ORION IR PROgRAMMINg