Badger Meter ORION Classic (CE) User Manual

Page 52

Advertising
background image

Profile Extraction Fields and Buttons

S/N

Displays the serial number of the ORION Migratable endpoint

IR / RF

Extract profile data via IR or RF Tap the box to select

Days

Drop-down menu used to select the number of days for the profile extraction Available choices:

7, 14, 30, 60, All (90)

Read Res.

Tap to see a list of test circles for the encoder

Oldest Reading

The date and time of the oldest reading in the extracted data

Interval

The reading interval at which the endpoint is set: 60 (every hour) or 15 (every quarter hour)

Quantity

The number of interval reads extracted from the endpoint

Status(es)

Displays any potential issues that require attention Example: tamper, no usage, etc

Change Interval

Tap to change the reading interval for the endpoint A message asking for confirmation displays

before and after changing the interval All currently stored profile data is erased when the interval

is changed

Clear Endpoint

Tap to erase the stored historical interval data for the endpoint

Save

Saves the extracted data on the handheld The csv file can be viewed with the ORION Profile

Viewer software
A confirmation message displays to show where the file is saved on the handheld

The file location

path includes the endpoint serial number and the date and time

Example: \Program Files\Badger Field Applications\Mobile Read Net\ProfileExtraction\

LogFiles\30000264 20140205 115349 csv

Show Archived

Tap to show previously transferred profile data files

The chart below shows the number of readings collected for meters set at 60 minute (hourly) intervals and at 15 minute

(quarter hourly) intervals:

Available Profile Data

Extraction Intervals

Hourly Reads:

1 Read per Hour

24 Reads per Day

15 Minute Reads:
4 Reads per Hour
96 Reads per Day

7 days

168 reads (24 x 7)

672 (96 x 7)

14 days

336 reads (24 x 14)

1344 (96 x 14)

30 days

720 reads (24 x 30)

2160 (96 x 22 5)

60 days

1440 reads (24 x 60)

2160 (96 x 22 5)

All/ 90 days

2160 reads (24 x 90)

2160 reads (96 x 22 5)

NOTE:

N

The ORION Migratable (or Fixed Network in mobile mode) water endpoint is capable of storing up to 90 days of

hourly interval data, or 2160 hourly reads If the account is set up to read every 15 minutes – 4 readings per hour –

the data extracted reflects four (4) readings per hour and reaches the maximum 2160 reads in 22 5 days

(90 days / 4 = 22 5 days)