Performing a Quick Read - Single Endpoint

1 On the ORION Quick Read - Single screen, tap in the

S/N field and use the handheld keypad to enter the

serial number of an endpoint

2 Tap Start

Result: Readings from the endpoint fill in the fields of

the table and the More button becomes active.
Tap More to access more information and

additional commands

Tap Reset to clear the screen and begin the

read again

Tap Stop to stop the radio

3 To read another endpoint, double tap in the S/N

field to highlight the serial number Then use the

handheld keypad to enter a new serial number

Figure 73: ORION Quick Read - Single with data

Quick Read - More

Tap the More button on the Quick Read - Single screen to display the Advanced screen for ORION Migratable endpoints only

(Figure 74) The following information is available on the Advanced screen

Get Extended Status

Tap to display a screen with the endpoint extended status which includes meter size, model

type and units, as well as any status alerts Tap the View button to display the Extended Status

screen For more information about Extended Status, see

"Extended Status" on page 23

in the

IR Programming section.

Get Firmware Version

Tap to access and display the endpoint firmware version in the field

Get Date/Time

Tap to set the endpoint date and time using the handheld date and time

Get Location

Tap to set the latitude/longitude settings for the endpoint if a GPS antenna is present For more

information, see

"Setting gPS location Manually" on page 30

in the IR Programming section.

Flow Rate Study

The field to the right of the Start, Get, Save buttons displays the flow study results

Start

Tap to start a 7-day flow rate study

Get

Tap to get the results from the flow rate study

Save

Tap to save the flow rate study results