Badger Meter ORION Classic (CE) User Manual

Page 21

Advertising
background image

3 Using the handheld keypad, enter the RTR odometer value in the Reading field

Result: The reading box is highlighted (Figure 22) to indicate a new value is entered in the field but not yet programmed.

Leading zeros are not required, however it may be helpful to enter leading zeros as visual confirmation Only seven

digits can be entered when programming an endpoint, regardless of the meter size

4 Align the optical head of the IR cable with the ORION Migratable endpoint IR LED port and tap Program

Result: The endpoint is programmed with the new value and the reading box is no longer highlighted. See Figure 23.

Figure 22: New reading entered

Figure 23: New reading programmed

NOTE:

N

When programming an endpoint after clearing a tamper, verify that the programming and wire splicing were

successful Select ORION Quick Read - Single from the Menu to perform a Quick Read on the endpoint If the

endpoint still reports “Tamper” in the Status field, check the wire splices, repair as necessary and then repeat the

programming procedure above

DO NOT STOP AN ENDPOINT BEFORE FIXING A TAMPER. RESTARTING A STOPPED

ENDPOINT CLEARS THE HISTORICAL INTERVAL DATA (PROFILE DATA) AND PLACES FIXED

MODE ENDPOINTS INTO MOBILE MODE. ENDPOINTS IN MOBILE MODE MAY NOT REVERT

TO FIXED MODE FOR UP TO 48 HOURS.

ORION IR PROgRAMMINg

Page 21

April 2014

ORION® Endpoint Utility for Trimble® Ranger 3