Enc extended status – Badger Meter ORION Classic (CE) User Manual

Page 25

Advertising
background image

ENC Extended Status

Figure 27: Extended Status - AdE

The status indicators described below apply for an ORION Migratable or Fixed Network (in mobile mode) endpoint when

connected to an ADE encoder (ENC)

Status Indicator

Description

Mobile Mode

Endpoint is communicating in mobile transmission mode

IR Programmed

Endpoint has been reprogrammed via IR

Low Battery

Endpoint is reporting a low battery condition

Tamper

Endpoint is reporting a tamper condition This condition occurs when the wire between the register

and the endpoint is cut or shorted, or the encoder is not connected

Encoder Error

Device error reported by the endpoint when the encoder exhibits a temporary or permanent failure

to extract the current reading

No Usage

Endpoint is reporting a no usage condition This condition occurs when there is no water flow

registered over a 30-day time frame

Leak

Endpoint is reporting a potential condition when there is continuous usage over a 24-hour time

period without a non-usage period of about 2 hours

Reverse Flow

Encoder is reporting a reverse flow condition to the endpoint

Encoder Information Description

Size & Type

The size and type of the meter for which the encoder was programmed Tap the button to change

the meter size and type See

"IR Programming Meter Size, Type and Units of Measure (RTR, AdE)"

on page 28

for more information

Units

The units of measure as defined by the encoder: cubic meters, cubic feet, gallons, imperial gallons or

liters Tap the button to change the units See

"IR Programming Meter Size, Type and Units of Measure

(RTR, AdE)" on page 28

for more information

Encoder

The encoder protocol

Dials

The encoder dial resolution (4-, 5- or 6-dials) as reported from the encoder

NOTE:

N

Refer to the ORION Migratable Endpoint product data sheet, available at

www.badgermeter.com

, for

complete information