Chapter 3 _______________________________________________________________ Installation

VAISALA_______________________________________________________________________ 37

Maximum Cable Resistance Calculation for the
Barrier (Vaisala Order Code: 210664)

Calculation of the maximum cable length from barrier to transmitter:

General specifications of HMT360:

Supply voltage

U

in

= 24 V (12 ... 35 V)

Maximum current

I

out

= 20 mA

Minimum operating voltage for
HMT360

U

min

= 12 V (15 V with serial port)

Stahl 9001/51-280-091-141 (values taken from the specifications):

Rated operating voltage

U

N

= 20 ... 35 V

Transmitter supply voltage

U

S

= U

N

- 9.5 V, when

U

N

≤ 23.5 V

or U

S

= 14 V, when U

N

≥ 23.5 V

Maximum load

R

L

≤ 350 Ω

Cable resistance (as an example) R

cable

= 0.085 Ω/m/core (2 ×

0.085 Ω/m/pair)