Forward power low, Forward power high, Reflected power low – Apex Digital 5708009-C User Manual

Page 110: Reflected power high, Data byte (lsb), Data byte, Data byte (msb), Data field definition, Table 4-10. upload status bytes, First status bit

Advertising
background image

4-64

5708009-C

Advanced Energy

®

Bytes 0 and 1 of the upload packet contain information about the Apex generator; this
information appears as status bits (or status “flags”). The following table defines these
status bits:

In the first status byte, bit 13 (the active toggle bit) indicates, the status of the Profibus
interface. After the Apex generator has powered up, this bit’s continuous change
indicates that the Profibus interface is ready. During operation, a cessation of this
change indicates that a communication problem exists.

4

Forward power low

5

Forward power high

6

Reflected power low

7

Reflected power high

8

Data byte (LSB)

9

Data byte

10

Data byte

11

Data byte

12

Data byte (MSB)

13

Data field definition

Table 4-10. Upload Status Bytes

First Status Bit

8 = Control mode (with bit 9)
9 = Control mode (00 = User, 10 = Profibus)
10 = Setpoint status OK
11 = Reserved
12 = End of Target Life (EOTL)
13 = Active toggle bit
14 = Bus fault (high or low)
15 = Reserved

Second Status Bit

0 = Reserved
1 = Overtemperature condition
2 = Interlock mechanism open
3 = Momentary power failure
4 = Reserved
5 = Contactor not closed
6 = Reserved
7 = Output is on

Table 4-9. Configuration of Profibus Upload Packet (Inbytes)