Digital input, See wiring diagram 4-6 – Apex Digital 5708009-C User Manual

Page 52

Advertising
background image

4-6

5708009-C

Advanced Energy

®

6

19

DC BIAS/POWER
REGULATION

Digital

input

This pin is used in conjunction
with signal pin 7 to allow the
generator to regulate its power
based on an external feedback
signal. When a positive voltage
between 4 and 30 V is connected
to this pin (reference to ground
pin 19), the generator regulates
on the input voltage signal on pin
7 (DC BIAS INPUT).

0 to 10V = 0 to maximum rated
power output as defined by
configuration PIN position 2 in
Table 1-1.

See Wiring Diagram 4-6.

Note: When using this

regulation feature, the
setpoint must be given at
pin 5 (SETPOINT).
Setpoints cannot be
established through the
serial interface at this
time.

Table 4-1. User Port 25-Pin APEX Standard Pin Descriptions (Continued)

Signal

Pin

Return

Pin

Name

Signal

Type

Description