4-68

5708009-C

Advanced Energy

®

130

read

mainframe

software

version

number

Requests the version number of the
mainframe software. The returning packet
contains 5 ASCII characters—a 5-digit
number. This command is used in conjunction
with CMD 198 to obtain the version/revision
number of the mainframe software.

0

5 data byte

5 ASCII

characters

155

read control

method

Requests control mode (set by CMD 14).
Returning values: 2 = host, 4 = analog.

0

1 data byte

8-bit value

156

read active

target

Requests the number of the active target (set
by CMD 11).

0

1 data byte

8-bit value

157

read target

life

Requests the amount of life remaining (set by
CMD 12) in the active target you specify.
Two decimals are implied— 100 = 1 kWh.

1

4 data bytes
32-bit value

Table 4-11. Profibus Host Port Commands (Continued)

Command

Description

Number of

Transmit

Data Bytes

Number of

Response

Data Bytes