1 data byte 8-bit value, Byte 1 = recipe step number (can be 1 through 7), 3 data bytes 8-bit value 16-bit value – Apex Digital 5708009-C User Manual

Page 93: Byte 1 = recipe step number (1 through 7), 2 data bytes 16-bit value

Advertising
background image

5708009-C

4-47

Apex 1 to 5.5 kW Generator

16

allowable

deviation

Specifies a percentage that the generator can
be out of setpoint before it starts the out-of-
setpoint timer. Accepts a value of 1 to 99%.
(Readback command is 185.)

1 data byte

8-bit value

1

19

number of

recipe

steps

Specifies the number of recipe steps. Send 1
data byte that indicates the number of recipe
steps (0 through 5).

1 data byte

8-bit value

22

recipe step/

setpoint

Specifies setpoint for a recipe step. Send 3
data bytes.

• byte 1 = recipe step number (can be 1

through 7)

• bytes 2 and 3 = setpoint value (send least

significant byte first); the value must be
within the operating range of the Apex
unit (see “Output Electrical
Specifications” on page 3-6)

3 data bytes

8-bit value

16-bit value

23

recipe step/

run time

Sets the run time for the specified recipe step.
Send 3 data bytes.

• byte 1 = recipe step number (1 through

7)

• bytes 2 and 3 = run time in hundredths of

seconds or in joules (if the recipe is set
for joules mode; see CMD 28 to set
recipe type); send least significant byte
first

3 data bytes

8-bit value

16-bit value

28

recipe type

Sets the recipe for time or joules mode. Send
one data byte indicating the recipe type:

1 = time mode

2 = joules mode

1 data byte

8-bit value

40

host port

timeout

value

Sets the Host port timeout value. Accepts a
value of 2 to 500, representing 0.02 to 5.0 s.
(Readback command is 140.)

2 data bytes
16-bit value

1

Table 4-6. Host Port Commands for RS-232 with AE Bus (Continued)

Command

Description

Number of

Host Data

Bytes

Number of

Response

Data Bytes