1st status byte, 2nd status byte, 3rd status byte—fault flags – Apex Digital 5708009-C User Manual

Page 97: 4th status byte—fault flags, 4 data bytes 4—8-bit values

Advertising
background image

5708009-C

4-51

Apex 1 to 5.5 kW Generator

162

read

process

status

Requests report on process status; returning
packet contains the following bytes arranged
as follows.

1st status byte:

0 = unassigned
1 = unassigned
2 = recipe run is active
3 = unassigned
4 = unassigned
5 = output power (0 = off, 1 = on)
6 = RF on requested
7 = setpoint status (0 = within tolerance,

1 = out of tolerance)

2nd status byte:

0 = end of target life
1 = unassigned
2 = unassigned
3 = overtemperature
4 = unassigned
5 = unassigned
6 = unassigned
7 = interlock open

3rd status byte—fault flags

0 = nonmaskable interrupt
1 = bus fault
2 = high bus voltage
3 = unassigned
4 = low bus voltage
5 = out of setpoint
6 = unassigned interrupt
7 = unassigned

4th status byte—fault flags

0 = current limit
1 = contactor failure
2 = Profibus error
3 = unassigned
4 = unassigned
5 = unassigned
6 = unassigned
7 = CEX is locked

0

4 data bytes

4—8-bit

values

Table 4-6. Host Port Commands for RS-232 with AE Bus (Continued)

Command

Description

Number of

Host Data

Bytes

Number of

Response

Data Bytes