background image

5708009-C

4-19

Apex 1 to 5.5 kW Generator

4

6

RF POWER
ENABLE

Digital

input

RF output is enabled when a 4 to
30 V input (pin 9, RF ON BIAS,
can be used as a voltage source)
is present on this pin.

Note: The interlocks must be

satisfied and the setpoint
must be within the Output
power range before unit
will deliver power. See
Table 3-3. on page 3-6 for
the Output power range
specification.

See Wiring Diagram 4-17.

5

6

FORWARD/LOAD
POWER SETPOINT

Analog

input

This analog signal provides a
linearly scaled control of the
forward or load output power
depending on the regulation
mode (1 V per 1 kW output
power).

See Wiring Diagram 4-16.

Note: The interlocks must be

satisfied and the setpoint
must be within the Output
power range before unit
will deliver power. See
Table 3-3. on page 3-6 for
the Output power range
specification.

6

SIGNAL COMMON

Chassis

ground

This pin is Signal Common. Also
connected to Apex generator
chassis ground.

7

6

RF ON STATUS

Digital

output

+ 5 Vdc on this pin represents
RF ON.

See Wiring Diagram 4-18.

8

6

EXTERNAL BIAS

Voltage

reference

+15 Vdc provided to the User
port through a 5.62 k

Ω resistor.

See Wiring Diagram 4-20.

Table 4-2. User Port (15-pin) Connector Pins Exclusive for Configuration D (Continued)

Signal

Pin

Return

Pin

Name

Signal

Type

Description

Advertising