Requests external feedback limit (set by cmd6), 2 data bytes 16-bit value, Reports dissipated power – Apex Digital 5708009-C User Manual

Page 99: Reports the allowable setpoint deviation, 1 data byte 8-bit value

Advertising
background image

5708009-C

4-53

Apex 1 to 5.5 kW Generator

171

read ext

feedback

limit

Requests external feedback limit (set by
CMD 6)

Note: The response in data bytes 1 and 2

represent the user external feedback
limit (LSB first). It returns the user
external feedback limit.

2 data bytes
16-bit value

173 report

power

dissipation

Reports dissipated power

Note: The response in data bytes 1 and 2

represent dissipated power (LSB first).
It returns dissipated power.

2 data bytes
16-bit value

184

read out-of-

setpoint

interval

Requests how long the generator is
programmed to produce output that is not
equal to the programmed setpoint level
before shutting output off (set with CMD 15).

Note: Data bytes 1 and 2 represent the

unsigned integer value for out of
setpoint time interval (LSB first). It
reports how many seconds the
generator will produce output that is
not equal to the setpoint before turning
the output off.

2 data bytes
16-bit value

185

read

allowable

deviation

Requests what percentage the generator can
be out of setpoint before it starts the out-of-
setpoint timer (set with CMD 16).

Reports the allowable setpoint deviation

Note: The response reports the percentage (1

to 99) and the supply can be out of
setpoint before turning on the out-of-
setpoint timer.

1 data byte

8-bit value

Table 4-6. Host Port Commands for RS-232 with AE Bus (Continued)

Command

Description

Number of

Host Data

Bytes

Number of

Response

Data Bytes