3-5

Apex 1 to 5.5 kW Generator

ELECTRICAL SPECIFICATIONS

Table 3-2, Table 3-3, and Table 3-4 describe the input power, output power, and other
electrical specifications for the Apex generator. In some cases, the specifications for
all 1 to 5.5 kW Apex units are the same, but in other cases, unit specifications vary
depending on the options installed. In such cases, the specification table refers to the
PIN position that defines those specifications, lists the PIN and configuration options
that are available and, when appropriate, provides cross references to more
information on those options. For more information on using the PIN to identify
information applicable to your Apex unit, see “Using this Manual to Find Information
for Your Generator” on page 1-1
.

Input Power Specifications

Table 3-2 describes the input power specifications for the Apex generator.

Panel

Note: Varies according to the

option defined by PIN
position 5.

0—on-board frame mount

1—Integrated rack-mount with blank panel

2—Integrated rack-mount with passive digital display

3—Integrated rack-mount with active digital display

4—exclusive option #1

RF measurement option

Note: Varies according to the

option defined by PIN
position 12.

0—Coupler

1—V/I probe

Table 3-1. Physical Specifications (Continued)

Description

PIN Option—Specification

Table 3-2. Input Power Specifications

Description

PIN Option and Specification

Line voltage

Note: Varies according to the

option defined by PIN
position 3.

0—208 V nominal, 187 to 229 Vac, 3

φ

1—400 V nominal, 360 to 440 Vac, 3

φ

2—n/a

3—208 V nominal, 187 to 229 Vac, 3

φ

4—400 V nominal, 360 to 440 Vac, 3

φ

Advertising