Environmental specifications, Table 3-6. climatic specifications, Class 3k3 – Apex Digital 5708009-C User Manual

Page 46: 5˚c to +40˚c, 41˚f to +104˚f, Class 3k2, 10% to 85% 1, 2 g/m3 to +25 g/m3, 80 kpa to 106 kpa, Class 1k4

Advertising
background image

3-14

5708009-C

Advanced Energy

®

ENVIRONMENTAL SPECIFICATIONS

Table 3-6 and Table 3-7 provide climatic and other environmental specifications for
the Apex generator.

Table 3-7 shows other environmental specifications for the Apex generator.

Table 3-6. Climatic Specifications

Temperature

Relative Humidity

Air Pressure

Operating

Class 3K3

5

°

C to +40

°

C

+41

°

F to +104

°

F

Class 3K2

10% to 85%

1

+2 g/m

3

to +25 g/m

3

Class 3K3

80 kPa to 106 kPa

800 mbar to 1060 mbar
(approximately 2000 m
above sea level)

Storage

Class 1K4

-25

°

C to +55

°

C

-13

°

F to +131

°

F

Class 1K3

5% to 95%

+1 g/m

3

to +29 g/m

3

Class 1K4

80 kPa to 106 kPa

800 mbar to 1060 mbar
(approximately 2000 m
above sea level)

Transportation

Class 2K3

-25

°

C to +70

°

C

-13

°

F to +158

°

F

Class 2K3

95%

2

+60 g/m

3

3

Class 2K3

66 kPa to 106 kPa

660 mbar to 1060 mbar
(approximately 3265 m
above sea level)

1

Non-condensing

2

Maximum relative humidity when the unit temperature slowly increases, or when the unit

temperature directly increases from -25°C to +30°C

3

Maximum absolute humidity when the unit temperature directly decreases from +70°C to

+15°C

Table 3-7. Environmental Specifications

Description

Specification

Overvoltage

Category II

Pollution Degree

2

Advertising