4-18

5708009-C

Advanced Energy

®

Unless otherwise specified, all analog signals are 0 to 10V while all digital signals are
0 to 5V.

PIN DESCRIPTIONS FOR OPTION D USER PORT

Table 4-2 provides the connector pin descriptions for the User port interface.

Table 4-2. User Port (15-pin) Connector Pins Exclusive for Configuration D

Signal

Pin

Return

Pin

Name

Signal

Type

Description

1

6

POWER LIMIT
STATUS

Digital

output

When a +5 V signal is present at
this pin a power limit is
encountered; signal low
represents normal operation.

See Wiring Diagram 4-19.

2

6

REFLECTED
POWER MONITOR

Analog

output

This analog signal provides a
linearly scaled readback of the
reflected power (1 V per 1 kW
reflected power).

See Wiring Diagram 4-15.

3

6

FORWARD/LOAD
POWER MONITOR

Analog

output

This analog signal provides a
linearly scaled readback of the
forward power (when the
generator is operated in forward
power regulation mode) or the
load power (when operated in
load power regulation mode).
(1 V per 1 kW forward/load
power).

See Wiring Diagram 4-14.

Advertising