164 read setpoint/ regulation mode, First and second bytes = setpoint value, Third byte = method of output regulation – Apex Digital 5708009-C User Manual

Page 116: 3 data bytes 16-bit value 8-bit value, 165 read forward power, 2 data bytes 16-bit value, 166 read reflected power, 167 read delivered power, 168 read ext feedback (dc bias), 169 read fwd pwr limit

Advertising
background image

4-70

5708009-C

Advanced Energy

®

164

read

setpoint/

regulation

mode

Requests output setpoint level (set by CMD 8)
and whatever method of output regulation has
been selected (set by CMD 3). The return
packet is arranged as follows:

First and second bytes = setpoint value.

Third byte = method of output regulation.

0

3 data bytes
16-bit value

8-bit value

165

read

forward

power

Requests a snapshot of forward power level at
that instant.

0

2 data bytes
16-bit value

166

read

reflected

power

Requests a snapshot of reflected power level
at that instant.

0

2 data bytes
16-bit value

167

read

delivered

power

Requests a snapshot of load power level at
that instant.

0

2 data bytes
16-bit value

168

read ext

feedback (dc

bias)

Requests a snapshot of external feedback level
at that instant.

0

2 data bytes
16-bit value

169

read fwd

pwr limit

Requests programmed limit for forward power
(set by CMD 4).

0

2 data bytes
16-bit value

170

read refl

pwr limit

Requests reflected power limit (set by
CMD 5).

0

2 data bytes
16-bit value

171

read ext

feedback

limit

Requests external feedback limit (set by
CMD 6).

0

2 data bytes
16-bit value

184

read out-of-

setpoint
interval

Requests how long the generator is
programmed to produce output that is not
equal to the programmed setpoint level before
shutting output off (set with CMD 15).

0

2 data bytes
16-bit value

Table 4-11. Profibus Host Port Commands (Continued)

Command

Description

Number of

Transmit

Data Bytes

Number of

Response

Data Bytes