Acceptable ranges for testing equipment – Balboa Water Group BP 60Hz User Manual

Page 23

Advertising
background image

23

Manufactured under one or more of these patents. U.S. Patents: 5332944, 5361215, 5550753, 5559720, 5,883,459, 6253227, 6282370, 6590188, 6976052, 6965815, 7030343, 7,417, 834 b2,

Canadian Patent: 2342614, Australian patent: 2373248 other patents both foreign and domestic applied for and pending. All material copyright of Balboa Water Group.

42211B

VOLTAGE CHECKLIST

All voltages specified as 120 V or 240 V, may show an
acceptable variance of +/- 10%.

Voltage Ranges

Wire Combo

Voltage +/- 10% Range

Black & Red

240 V 216 V -264 V

Black & White 120 V 108 V -132 V

Red & White

120 V 108 V - 132 V

Black& Green

120 V 108 V - 132 V

Red & Green

120 V 108 V - 132 V

Green & White 0 V

*

*

* Depending on variables such as length of run,

type of wire and temperature, small voltage readings may
sometimes occur between ground and neutral.

MOTOR AMPERAGE GUIDELINES

The following ranges represent general parameters
for many different motors and applications. Check the
device label or with the spa manufacturer to get accurate
amperage draws.

AMPERAGE DRAW RANGES

DEVICE

120 V DRAW

240 V DRAW

Pump low

2 A - 5 A

2 A - 4 A

Pump high

10 A - 14 A

8 A - 12 A

Blower

6 A - 8 A

3 A - 4 A

Acceptable Ranges for Testing Equipment

ACCEPTABLE HEATER AMPERAGE DRAW RANGES

Heater Type

120V Amp Draw

240V Amp Draw

5.5 kW @ 240 V

10.42 A - 12.74 A

20.83 A - 25.48 A

4 kW @ 240 V

7.58 A - 9.26 A

15.15 A -18.52 A

1 kW @ 120 V

7.58 A - 9.26 A

-

ACCEPTABLE HEATER OHM (

Ω) RANGES

Heater Type

Ohms (

Ω

)

5.5 kW @ 240 V

9.42

Ω

-11.52

Ω

4 kW @ 240 V

12.96

Ω

-15.84

Ω

1 kW @ 120 V

12.96

Ω

- 15.84

Ω

TEMPERATURE & HIGH-LIMIT SENSOR OHM TABLE

Temp.

of Sensor

Ohms

(k

Ω

)**

Temp. of

Sensor

Ohms

(k

Ω

)**

40° F

76.686 k

Ω

90° F

22.117 k

Ω

45° F

67.112 k

Ω

100° F

17.636 k

Ω

50° F

58.858 k

Ω

105° F

15.788 k

Ω

60° F

110° F

14.158 k

Ω

70° F

35.533 k

Ω

115° F

12.716 k

Ω

80° F

27.93J k

Ω

120°F

11.439

k

Ω

**Note: 1 k

Ω

= 1000

Ω :

k

Ω

may vary +/- 10% depending on the accuracy of the thermom-

eter and meter used.

Heater Type

Ohms

120V Amp Draw 120V Watts 240V Amp Draw 240V Watts

230V Amp Draw

230V Watts

5.5Kw @ 240V

10.472

11.458

1.37Kw

22.916

5.5Kw

21.961

5.05Kw

5.2Kw @ 240V

11.076

10.834

1.3Kw

21.666

5.2Kw

20.765

4.8Kw

4Kw @ 240V

14.4

8.333

1Kw

16.666

4Kw

15.972

3.7Kw

3Kw @ 240V

19.2

6.25

750W

12.5

3Kw

11.979

2.8Kw

2Kw @ 240V

28.8

4.166

500W

8.333

2Kw

7.986

1.8Kw

1Kw @ 120V

14.4

8.333

1Kw

N/A

N/A

N/A

N/A

HEATER MATRIX

Advertising