Troubleshooting Heater Resistance

TROUBLESHOOTING HEATER RESISTANCE

Locate the heater connector.

Disconnect the connector by depressing the tab.

Pull the connector straight out.

Place the meter probes on the heater terminals.

Release tab

Release tab

ACCEPTABLE HEATER OHM (

Ω) RANGES

Heater Type

Ohms (

Ω

)

5.5 kW @ 240 V

9.42

Ω

-11.52

Ω

4 kW @ 240 V

12.96

Ω

-15.84

Ω

1 kW @ 120 V

12.96

Ω

- 15.84

Ω

**Note: 1 k

Ω

= 1000

Ω :

k

Ω

may vary +/- 10% depending on the accuracy of

the meter used.

TEST IS WITH POWER OFF