Testing heater amperage – Balboa Water Group BP 60Hz User Manual

Page 41

Advertising
background image

41

Manufactured under one or more of these patents. U.S. Patents: 5332944, 5361215, 5550753, 5559720, 5,883,459, 6253227, 6282370, 6590188, 6976052, 6965815, 7030343, 7,417, 834 b2,

Canadian Patent: 2342614, Australian patent: 2373248 other patents both foreign and domestic applied for and pending. All material copyright of Balboa Water Group.

42211B

AMPERAGE HEATER TEST BP2000G1

AMPERAGE HEATER TEST BP500

CAUTION - TEST IS WITH POWER ON

Testing Heater Amperage

ACCEPTABLE HEATER AMPERAGE DRAW RANGES

Heater Type

120V Amp Draw

240V Amp Draw

5.5 kW @ 240 V

10.42 A - 12.74 A

20.83 A - 25.48 A

4 kW @ 240 V

7.58 A - 9.26 A

15.15 A -18.52 A

1 kW @ 120 V

7.58 A - 9.26 A

-

PLACE CLAMP AROUND ONE HEATER WIRE, AND THEN THE OTHER WIRE.

Advertising