Testing heater amperage – Balboa Water Group BP 60Hz User Manual
Page 41
Advertising
41
Manufactured under one or more of these patents. U.S. Patents: 5332944, 5361215, 5550753, 5559720, 5,883,459, 6253227, 6282370, 6590188, 6976052, 6965815, 7030343, 7,417, 834 b2,
Canadian Patent: 2342614, Australian patent: 2373248 other patents both foreign and domestic applied for and pending. All material copyright of Balboa Water Group.
42211B
AMPERAGE HEATER TEST BP2000G1
AMPERAGE HEATER TEST BP500
CAUTION - TEST IS WITH POWER ON
Testing Heater Amperage
ACCEPTABLE HEATER AMPERAGE DRAW RANGES
Heater Type
120V Amp Draw
240V Amp Draw
5.5 kW @ 240 V
10.42 A - 12.74 A
20.83 A - 25.48 A
4 kW @ 240 V
7.58 A - 9.26 A
15.15 A -18.52 A
1 kW @ 120 V
7.58 A - 9.26 A
-
PLACE CLAMP AROUND ONE HEATER WIRE, AND THEN THE OTHER WIRE.