Balboa Water Group BP 60Hz User Manual

Page 26

Advertising
background image

26

Manufactured under one or more of these patents. U.S. Patents: 5332944, 5361215, 5550753, 5559720, 5,883,459, 6253227, 6282370, 6590188, 6976052, 6965815, 7030343, 7,417, 834 b2,

Canadian Patent: 2342614, Australian patent: 2373248 other patents both foreign and domestic applied for and pending. All material copyright of Balboa Water Group.

4/22/13

W

iri

ng Diagr

am - BP2000G

1,

Par

t Number 5637

7 (

con

t.)

A1

A2

A3

A4

A5

A6

A7

A8

A9

A10

SWITCHBANK S1 OFF

SWITCHBANK S1 ON

PART B

BP2000G1 – PN 56377

10-23-12

USE EARTH GROUND CONNECTIONS AS INDICATED INSIDE THE SYSTEM ENCLOSURE

TOTAL OUTPUT AMP DRAW NOT TO EXCEED MAX INPUT RATING OF SPA

A DISCONNECTING MEANS MUST BE INSTALLED WITHIN SIGHT FROM

THE EQUIPMENT AND AT LEAST 5 FEET (1.52 M) FROM THE

INSIDE WALLS OF THE POOL, SPA, OR HOT TUB.

CONNECT ONLY TO CIRCUITS PROTECTED BY A CLASS A GFCI.

FOR SUPPLY CONNECTIONS, USE CONDUCTORS SIZED ON THE BASIS OF

60°C AMPACITY BUT RATED MINIMUM OF 90°C.

TORQUE RANGE FOR MAIN TERMINAL BLOCK (TB1): 27-30 IN. LBS. (31.1-34.5 kg cm)

USE COPPER CONDUCTORS ONLY. EMPLOYER UNIQUEMENT DES CONDUCTEURS DE CUIVRE. #6 AWG MIN. WIRE = 90°

1

NONE

2-SPEED

2-SPEED

2-SPEED

NONE

°F

2

NONE

2-SPEED

2-SPEED

1-SPEED

NONE

°F

3

NONE

2-SPEED

2-SPEED

NONE 1-SPEED °F

4

NONE

2-SPEED

2-SPEED

NONE NONE °F

5‡

NONE

2-SPEED

1-SPEED

1-SPEED

1-SPEED

°F

6

NONE

2-SPEED

1-SPEED

1-SPEED

NONE

°F

7

PROGRAMMABLE FILTRATION + POLLING

2-SPEED

2-SPEED

2-SPEED

NONE

°F

8

PROGRAMMABLE FILTRATION + POLLING

2-SPEED

2-SPEED

1-SPEED

NONE

°F

9

PROGRAMMABLE FILTRATION + POLLING

2-SPEED

2-SPEED

NONE

1-SPEED

°F

10

PROGRAMMABLE FILTRATION + POLLING

2-SPEED

2-SPEED

NONE

NONE

°F

11‡

PROGRAMMABLE FILTRATION + POLLING

2-SPEED

1-SPEED

1-SPEED

1-SPEED

°F

12‡

PROGRAMMABLE FILTRATION + POLLING

1-SPEED

1-SPEED

1-SPEED

1-SPEED

°F

13

PROGRAMMABLE FILTRATION + POLLING

2-SPEED

1-SPEED

1-SPEED

NONE

°F

14

PROGRAMMABLE FILTRATION + POLLING

1-SPEED

1-SPEED

1-SPEED

NONE

°F

15‡ NONE 2-SPEED

2-SPEED

1-SPEED

1-SPEED

°F

16‡

PROGRAMMABLE FILTRATION + POLLING

2-SPEED

2-SPEED

1-SPEED

1-SPEED

°F

SETUP #

CIRC PUMP

PUMP 1

PUMP 2

PUMP 3

BLOWER

TEMP SCALE

* FOR 240V CIRC PUMP AND OZONE, CONNECT J20 TO J42 (IN GROUP 2)

INSTEAD OF

SETUP #1,

THIS SYSTEM IS

CONFIGURED IN

SETUP #:

PUMP 1 LOW TIMEOUT IS 15 MINUTES.

‡SETUPS 5, 11, 12, 15 AND 16 REQUIRE BP2X-WIRE KIT PN30893

LOCATION DEVICE

VOLTS

MAX

AMPS

FROM

TO

J9

2-SP PUMP 1

240V

12A MAX

J46

J72-GROUP 2

J14

AUX

240V

12A MAX

J18

J3-GROUP 2

AUX LINE 1 CONNECTION

J19

J43

J15 SPA

LIGHT

12V

1A

J21

CIRC PUMP

120V*

2A MAX

J20

J79-GROUP 4

J32 OZONE

1A

CIRC AND OZONE LINE 1 CONNECTION

J81

J59

J33

TV / AV

120V

3A

J38

J45-GROUP 4

J44 HEATER 240V

5.5

kW

TO

J1 ON

EXPANDER

TO RED AC (GROUP 2)

ON MAIN BOARD

SPLITTER OPTIONS:

IN SETUPS 5, 11, 12 S1 = PUMP 2 S3 = PUMP 3

IN SETUPS 15, 16 S1 = PUMP 3 S3 = FUSED ADAPTER

SPLITTER IS UNUSED (REMOVED) IN SETUPS 1-4, 6-10, 13, 14,

SETUPS 15 AND 16 REQUIRE THE ADDITIONAL FUSED ADAPTER FOR BLOWER OUTPUT

WHITE

RED

WHITE

GREEN

GREEN

BLACK

S1

12A MAX

S2

12A MAX

FUSED ADAPTER

‡ OPTIONAL BP2X-WIRE KIT PN 30893

TO S2

SETUPS

15 & 16 ONLY

BLOWER

10A

TEST MODE OFF

DON’T ADD 1 HS PUMP W/HTR

DON’T ADD 2 HS PUMPS W/HTR

DON’T ADD 4 HS PUMPS W/HTR

SPECIAL AMPERAGE RULE A

STORE SETTINGS**

1 MIN HTR COOLDOWN (ELEC)

NOT ASSIGNED

NOT ASSIGNED

NOT ASSIGNED

TEST MODE ON

ADD 1 HS PUMP WITH HEAT

ADD 2 HS PUMPS WITH HEAT

ADD 4 HS PUMPS WITH HEAT

SPECIAL AMPERAGE RULE A

MEMORY RESET**

5 MIN HTR COOLDOWN (GAS)

NOT ASSIGNED

NOT ASSIGNED

NOT ASSIGNED

** SWITCH #

6

SHOULD BE SET TO OFF UPON FINAL INSTALLATION.