TEST IS WITH POWER OFF

TROUBLESHOOTING HEATER POSTS RESISTANCE TO HEATER HOUSING

VERIFY THAT THERE IS NO HEATER “LEAKAGE”

Measure resistance from a heater post to the

heater housing

Verify there is NO continuity from the heater post

to the heater housing or heater current collector

connection. The meter reading shown is OL,

indicating infinite resistance.

Verify there is NO continuity from the heater post to

the ground/earth. On the resistance scale, the a digital

meter should read OL (indicating infinite resistance).

Troubleshooting Heater Posts Resistance to Heater Housing

Locate the heater connector.

Disconnect the connector by depressing the tab.

Pull the connector straight out.

Release tab

Release tab