Balboa Water Group BP 60Hz User Manual

Page 30

Advertising
background image

30

Manufactured under one or more of these patents. U.S. Patents: 5332944, 5361215, 5550753, 5559720, 5,883,459, 6253227, 6282370, 6590188, 6976052, 6965815, 7030343, 7,417, 834 b2,

Canadian Patent: 2342614, Australian patent: 2373248 other patents both foreign and domestic applied for and pending. All material copyright of Balboa Water Group.

4/22/13

A1

A2

A3

A4

A5

A6

A7

A8

A9

A10

SWITCHBANK S1 OFF

SWITCHBANK S1 ON

PART B

BP20MSSH – PN 56373

01-03-13

USE EARTH GROUND CONNECTIONS AS INDICATED INSIDE THE SYSTEM ENCLOSURE

TOTAL OUTPUT AMP DRAW NOT TO EXCEED MAX INPUT RATING OF SPA

A DISCONNECTING MEANS MUST BE INSTALLED WITHIN SIGHT FROM

THE EQUIPMENT AND AT LEAST 5 FEET (1.52 M) FROM THE

INSIDE WALLS OF THE POOL, SPA, OR HOT TUB.

CONNECT ONLY TO CIRCUITS PROTECTED BY A CLASS A GFCI.

FOR SUPPLY CONNECTIONS, USE CONDUCTORS SIZED ON THE BASIS OF

60°C AMPACITY BUT RATED MINIMUM OF 90°C.

TORQUE RANGE FOR MAIN TERMINAL BLOCK (TB1): 27-30 IN. LBS. (31.1-34.5 kg cm)

USE COPPER CONDUCTORS ONLY. EMPLOYER UNIQUEMENT DES CONDUCTEURS DE CUIVRE. #6 AWG MIN. WIRE = 90°

1

PROGRAMMABLE FILTRATION + POLLING

2-SPEED

2-SPEED

1-SPEED

°F

2

PROGRAMMABLE FILTRATION + POLLING

2-SPEED

1-SPEED

1-SPEED

°F

3

PROGRAMMABLE FILTRATION + POLLING

2-SPEED

NONE

1-SPEED

°F

4

NONE

2-SPEED

2-SPEED

1-SPEED

°F

5

NONE

2-SPEED

1-SPEED

1-SPEED

°F

6

NONE

2-SPEED

NONE

1-SPEED

°F

SETUP #

CIRC PUMP

PUMP 1

PUMP 2

MICROSILK®

TEMP SCALE

SYSTEM WILL BE IN

SETUP #1

INSTEAD OF

SETUP #1,

THIS SYSTEM IS

CONFIGURED IN

SETUP #:

PUMP 1 LOW TIMEOUT IS 15 MINUTES.

PUMP 2 IS 2-SPEED IN SETUPS 1 & 4

PUMP 2 IS 1-SPEED IN SETUPS 2 & 5

PUMP 2 IS NOT USED IN SETUPS 3 & 6

LOCATION DEVICE

VOLTS

MAX

AMPS

FROM

TO

J9

2-SP PUMP 1

240V

12A MAX

J46

J72-GROUP 2

J14

2-SP PUMP 2

240V

12A MAX

J18

J3-GROUP 2

PUMP 2 LINE 1 CONNECTION

J19

J10

J15 SPA

LIGHT

12V

1A

J21

CIRC PUMP

120V*

2A MAX

J20

J79-GROUP 4

J32 OZONE

1A

CIRC AND OZONE LINE 1 CONNECTION

J81

J59

J33

TV / AV

120V

3A

J38

J78-GROUP 4

J44 HEATER 240V

5.5

kW

* FOR 240V CIRC PUMP AND OZONE, CONNECT J20 TO J42 (IN GROUP 2)

MICROSILK IS A REGISTERED TRADEMARK OF JASON INTERNATIONAL

TEST MODE OFF

DON’T ADD 1 HS PUMP W/HTR

DON’T ADD 2 HS PUMPS W/HTR

DON’T ADD 4 HS PUMPS W/HTR

SPECIAL AMPERAGE RULE A

STORE SETTINGS*

NOT ASSIGNED

NOT ASSIGNED

NOT ASSIGNED

NOT ASSIGNED

TEST MODE ON

ADD 1 HS PUMP WITH HEAT

ADD 2 HS PUMPS WITH HEAT

ADD 4 HS PUMPS WITH HEAT

SPECIAL AMPERAGE RULE B

MEMORY RESET*

NOT ASSIGNED

NOT ASSIGNED

NOT ASSIGNED

NOT ASSIGNED

*SWITCH #

6

SHOULD BE SET TO OFF UPON FINAL INSTALLATION.

W

iri

ng Diagr

am - BP2

0MSSH, Par

t Number

: 5637

3 (

M

icr

oSilk

, con

t.)

Advertising