102°f, Component failure and replacement testing, Software setups and test mode – Balboa Water Group BP 60Hz User Manual

Page 46

Advertising
background image

46

Manufactured under one or more of these patents. U.S. Patents: 5332944, 5361215, 5550753, 5559720, 5,883,459, 6253227, 6282370, 6590188, 6976052, 6965815, 7030343, 7,417, 834 b2,

Canadian Patent: 2342614, Australian patent: 2373248 other patents both foreign and domestic applied for and pending. All material copyright of Balboa Water Group.

4/22/13

Software Setups and Test Mode

All BP systems have the capability for Test Mode. Test Mode is
used when changing setup configurations through the panel,
which also means that wiring changes may be necessary. (See
the specific spa control system Tech Sheet for more details.)
Note: Although Test Mode allows access to certain utility fea-
tures, most Utilities are available without entering Test Mode.
A/B Sensor Temperatures and Fault Log information are present-
ed here since they appear on the Test menu screen (see below).

DANGER! HIGH VOLTAGE WILL BE ACCESSIBLE!

SERVICE TECHNICIAN ONLY!

TEST MENU ACCESS (S1, SWITCH 1 ON)

SOFTWARE SETUPS

Under the TEST Menu, the Setup screen will allow changing the
Setup from 1 to any number established by the manufacturer.
Changing the Setup may require wiring changes as well.

While the system is running, move

1.

DIP Switch 1 (on S1 on

the Main circuit board) to ON.
The system will enter

2.

Test Mode. On the home screen

(below) will appear the word TEST.

3. Change the setup to the desired setup configuration number

(depending on DIP switch or wires changes, if any).

(Test Mode On) Test > Setup

Moving DIP Switch 1 to OFF will exit Test Mode

4.

The Control System is in Test Mode if 102˚T appears.
(In this case °F or °C is replaced by °T.)

Set:

104°F

8:32 PM
Ozone
Filter 1

Spa

Shortcuts

Settings

Test

High Range

102°F

Ready in Rest Mode
Heating

`

ON

1

10

S1

Test

Back

Setup

A/B Temps
Fault Log
Timeouts
Temp Limit

1

`

Off

`

Normal
Yes

OTHER TEST MODE FEATURES:

A/B TEMPS (A/B SENSOR TEMPERATURES)

When this is set to On, the temperature display will alternate to
display temperature from Sensor A and Sensor B in the heater.

FALT LOG (FAULT LOG)

The Fault Log is a record of the last 24 faults that can be
reviewed by a service tech.

DEMO (DEMO MODE)

Demo Mode is not always enabled, so it may not appear. This
is designed to operate several devices in a sequence in order to
demonstrate the various features of a particular hot tub.

TIME OUTS

Used only by the manufacturer for specific tests.

TEMP LIMIT

Used only by the manufacturer for specific tests.

VIEWING CONFIGURATION SETTINGS

There are times when a technician may want to view the con-
figuration settings (or, config. setup) before working on a system.
View the configurations in the following way:
TP900/TP800 panels: System Information > Current Setup
TP600/TP400 panels:

UTIL > INFO > SETP (Standard Menus)

TP600/TP400 panels with Simplified Menus can only access
the configuration setup when in test mode.
Note: In the event that a panel stops operating, a good working
panel plugged into the system will reveal the config. settings as
they are held in memory.

Component Failure and Replacement Testing

-

Advertising