Airlink EDGE/GPRS User Manual

Page 91

Advertising
background image

PinPoint-E EDGE/GPRS - User Guide, version 2.32

85

AT Commands: Serial

\Q

*CTSE=n

*MODEMHISPEED

*NUMTOIP=n

Cannot be configured in Wireless Ace.

Set or query the serial port flow control setting.

n=0 : No flow control is being used.

n=1 : RTS/CTS hardware flow control is being used.

n=4: Transparent software flow control. Uses escaped XON and XOFF for flow control. XON and
XOFF characters in data stream are escaped with the @ character (0x40). @ in data is sent as @@.

Clear To Send Enable: This feature asserts CTS when there is a network connection.

n=0 : Disabled (Default).

n=1 : Enable assertion of CTS when there is network coverage.

RS232 voltage levels:

Positive = Network coverage.

Negative = No coverage.

Note:

Flow control (AT\Q) will override this indication, so if you want to use CTS

to indicate network coverage, flow control has to be off (AT\Q0).

Set the internal serial link speed to the radio (modem) module.

May not be available for all modem models.

Convert 12 digit number to IP.

n=0 : Use as name.

n=1 : Use as IP address.