Safety Precautions

10

CAFS Air Bottle Installer/Operation Guide

p/n: 029-0020-85-0

Also see Tescom “Safety, Installation and Operation Precautions” guide
lines, located at the back of this manual.

If a balancing regulator valve or other component in the system shows
signs of a leak or malfunction, the CAFSAttack system must be removed
from service immediately and repaired and tested before retuning to
service.

DANGER !

ONCE THE AIR CYLINDERS ARE FULLY CHARGED AND THE SYSTEM IS
ENERGIZED, ALL HIGH PRESSURE LINES BETWEEN THE CYLINDER SHUT-
OFF VALVES AND THE PRESSURE BALANCING REGULATOR VALVES,
INCLUDING THE AIR FILTER, ARE EXPOSED TO HIGH PRESSURES (4,500
PSI / 310 BAR).

DO NOT PERFORM ANY SERVICE TO THE HIGH PRESSURE SIDE UNTIL THE
SYSTEM PRESSURE IS RELIEVED. SEE SECTION “6.3 RELIEVING HIGH
PRESSURE,” ON PAGE 59 FOR ADDITTIONAL INFORMATION.

DO NOT operate the system with just air and water. Shut off the air sup-
ply whenever the foam tank is empty.

CAUTION !

COLD WEATHER ENVIRONMENTS CAN CAUSE SOME COMPONENTS TO
FREEZE AND RESTRICT AIR FLOW. COMPONENTS MUST BE THAWED
BEFORE CONTINUING CAFS OPERATION.

NEVER fully empty the air-bottle cylinders. Always maintain a positive
pressure (approximately 50 to 100 PSI / 4 to 7 BAR) within the cylinders.
Positive pressure ensures against moisture and/or dirt contamination in
the tanks, which could also flow back and contaminate the SCBA
recharging cylinders.

Failure to comply could result in serious bodily injury, sickness or
death.

To prevent electrical shock always disconnect the primary power source
before attempting to service any part of the CAFSAttack system.

All electrical systems have the potential to cause sparks during service.
Take the necessary precautions to eliminate explosive or hazardous
environments during any installation and/or service.

To prevent system damage or electrical shock, the main power supply
wire must be the last connection made to the CAFSAttack system.

The CAFSAttack system is designed for use on negative (-) ground,
direct current, electrical systems only.