Description

16

CAFS Air Bottle Installer/Operation Guide

p/n: 029-0020-85-0

Figure 2-1: CAFSAttack System Overview

HIGH pressure valve assembly - continued

Tee-type air filter - used to remove any particulate contaminates from
the system. A multi-layered glass fiber element produces high effi-
ciency silt-control filtration and provides for extended service intervals
and reduced maintenance cost.

A visual pressure indicator enables the operator to read contaminated
build up before the element is plugged, with an automatic reset.

Two electrically-controlled open/close air shut-off valves.

Pressure safety relief valve, set at 165 PSI (11.4 BAR).

Pressure safety relief Rupture Disc, set at 350 PSI (24 BAR).

Check valves to ensure separation of water, foam solution, foam con-
centrate and air.

Discharge Manifold

Two electrically-controlled shut-off valves, with valve position
indicator.

See separate SVS manual provided (Hale p/n: 209-0020-90-0) for
additional valve information.

Mixing chambers.