Primary power and ground – Hale CAFS Attack User Manual

Page 42

Advertising
background image

Installer Installation

42

CAFS Air Bottle Installer/Operation Guide

p/n: 029-0020-85-0

IMPORTANT - continued !

WHEN PLANING CABLE RUNS MAKE SURE THE WIRES ARE ROUTED BY
THEIR SHORTEST MOST DIRECT ROUTE, STABILIZED AGAINST EXCESSIVE
VIBRATION AND ROUTED TO AVOID INTERFERENCE WITH THE APPARATUS
OPERATORS.

For complete cable design of the standard harness (Class1 p/n: 112757)
and for the Triple Discharge Option harness (Class1 p/n: 114810), also see
Section 8, heading “Drawing / Manual Package” on page 67.

Primary Power and Ground

CAUTION !

PREVENT CORROSION OF POWER AND GROUND CONNECTIONS BY SEAL-
ING THESE CONNECTIONS WITH SILICONE SEALANT.

DO NOT CONNECT THE MAIN POWER LEAD TO SMALL LEADS THAT ARE
SUPPLYING SOME OTHER DEVICE, SUCH AS A LIGHT BAR OR SIREN. THE
CAFSATTACK SYSTEM REQUIRES

?? AMP

MINIMUM CURRENT.

USE MINIMUM 14 AWG TYPE SXL/GXL (SAE J1128) WIRE.

Primary electrical power must be supplied directly from the battery, the bat-
tery master disconnect switch or solenoids to the CAFSAttack harness,
connector #13.

RED

................... Power

BLACK .............. Ground

The primary power connection must be made so that power is supplied to
the CAFSAttack system when the main apparatus electrical system is ener-
gized. This ensures immediate operation when the operator places the
apparatus in PUMP mode, and to prevent battery power drain when the
apparatus is not running.

Be sure the CAFSAttack system is grounded to the chassis.

When making the ground connections make sure lugs are soldered to the
strap ends for trouble free connections. Seal all connection against
corrosion.