CAFS Air Bottle Installer/Operation Guide
p/n: 029-0020-85-0

In s talle r In sta llatio n

The following components are pre-mounted on the SVS discharge manifold
assembly. (See Figure 4-5: “Typical CAFSAttack SVS Discharge Manifold
Assembly,” on page 30.)

Electrically-operated Hale SVS valves, with valve position indicator.

See separate manual for description, installation and operation of the
SVS valves - Torrent SVS Valve Installation Operation and Maintenance
Manual, Hale p/n: 029-0020-90-0.

Mixing chambers, includes one 2.0” (51 mm) mixer insert.

Paddle wheel flow sensors (2).

1.

The SVS Hale pre-manufactured, flange-mounted stainless steel dis-
charge manifold is assembled and fully tested before leaving the factory.
When properly mounted, the flow sensor is on the side of the manifold
with one of the drain ports located at the bottom.

2.

The flow sensor should point upwards slightly to allow drainage of water
and sediment. (See Figure 4-5: “Typical CAFSAttack SVS Discharge
Manifold Assembly,” on page 30.)

3.

Mount the SVS discharge manifold assembly to the pump manifold dis-
charge port using the gasket and hardware provided.

4.

Apply a small amount of grease to the gasket before final installation,
then firmly tighten the four 7/16”-14 mounting bolts and torque to 33
ft.lbs. (45 N-m).

Note: The CAFS discharge connection from the SVS discharge manifold assem-
bly is 2” (51 mm) Victaulic.

4.7

PLUMBING

IMPORTANT !

WHEN PLANING INTERCONNECTING PLUMBING LINES MAKE SURE THEY
ARE ROUTED BY THEIR SHORTEST MOST DIRECT ROUTE, STABILIZED
AGAINST EXCESSIVE VIBRATION AND ROUTED TO AVOID INTERFERENCE
WITH THE APPARATUS OPERATORS.

CONNECTING ENDS OF HYDRAULIC TUBING, IF USED, MUST BE FLARED.
USE THREAD SEALING COMPOUND, FOR EXAMPLE, LOCTITE PST OR
EQUIVALENT, ON ALL PLUMBING CONNECTIONS.

A system block diagram is provided at the end of this manual.