Installer Installation

44

CAFS Air Bottle Installer/Operation Guide

p/n: 029-0020-85-0

NEVER attempt to shorten or lengthen these shielded cables. If necessary
order longer or shorter cables from Class1 to suit your particular installation
needs. Wire used is minimum 18 AWG type SXL/GXL (SAE J1128) Wire.

Discharge Valve, Electric Motor (MV1)

Connect the main cable harness (connectors #3 and #9) to the

?-pin

con-

nectors on the discharge air valve electric motors. (See Figure 4-16: “Pri-
mary CAFS Wire Harness,” on page 41.)

NEVER attempt to shorten or lengthen these shielded cables. If necessary
order longer or shorter cables from Class1 to suit your particular installation
needs. Wire used is minimum 16 AWG type SXL/GXL (SAE J1128) Wire.

On/Off Switch (SA3), Operator Control Panel

(See Figure 4-18: “On/Off Switch Connection.”)

Connect the red and
white wires from the
FoamLogix main
cable harness to the
connectors on the
back of the CAFS on/
off switch. (See Fig-
ure 4-16: “Primary
CAFS Wire Harness,”
on page 41.)

Use minimum 16
AWG type SXL/GXL
(SAE J1128) wire.

Figure 4-18: On/Off Switch Connection