CAFS Bottled-Air Operator/s Guide
p/n: 029-0020-85-0

St ar t Up Ch e ck L is t

WARNING ! - continued

THE HIGH PRESSURE SIDE IS BLED (PRESSURE RELIEVED) BY FIRST MAK-
ING SURE THE CYLINDER SHUT-OFF VALVE IS FULLY CLOSED. THEN
SLIGHTLY LOOSENING THE HOSE FITTING NUT AT THE CYLINDER SHUT-
OFF VALVE UNTIL YOU HEAR AIR ESCAPING FROM THE FITTING. AN
ALTERNATE METHOD IS TO INSTALL AND SHUT-OFF VALVE IN AN ACCES-
SIBLE AREA IN THE HIGH PRESSURE LINE. ALSO SEE HEADING “RELIEV-
ING HIGH PRESSURE” ON PAGE 59.

All LOW discharge pressure air lines are the proper size and type and all
connections are tight.

WARNING !

ONCE THE CYLINDERS ARE FULLY CHARGED AND THE SYSTEM IS ENER-
GIZED, THE DISCHARGE (LOW) PRESSURE LINES ARE EXPOSED TO LOW
PRESSURE (APPROXIMATELY 150 PSI / 10 BAR).

THE DISCHARGE LINES ARE BLED (PRESSURE RELIEVED) BY OPENING
THE CONDENSATION DRAIN VALVES.

The water line from the midship pump the pressure balancing regulator
valve dome port is the proper size and type and the connections are
tight.

Flow sensor mounted with flow arrow in the correct direction for water
flow.

Check valves are properly mounted in air lines. (See Figure 4-10: “Typi-
cal LOW Pressure CAFS Air Connections,” on page 36.) A
lso see Figure
4-5: “Typical CAFSAttack SVS Discharge Manifold Assembly” on page
30.

Air filter/strainer mounted for proper air flow direction.

All hoses are free of kinks and sharp bends. No sharp bends exist that
can trap air in the system.

Condensation discharge air line connections correct and tight.

Discharge piping is hydro-tested in accordance with NFPA / UL
requirements.

Air cylinder shut-off valve on the CAFSAttack operator’s panel is in the
CLOSED (O) position.

The CAFSAttack ENABLE on/off switch is in the OFF (O) position.