2 smart-switch controller (spc), Open button, discharge valve, Smart-switch controller (spc) – Hale CAFS Attack User Manual

Page 18

Advertising
background image

Description

18

CAFS Air Bottle Installer/Operation Guide

p/n: 029-0020-85-0

Since the system is of the modular design, a minimum number of pneumatic
and electrical connections are required.

Mounting the FoamLogix 2.1A, 3.3 or 5.0 System includes installation of
the foam pump and motor assembly, in-line strainer and valve assembly and
low tank sensor. Refer to the following manual, based on the specific model
FoamLogix included with your system:

FoamLogix Model 2.1A Installation and Operation Manual,
Hale p/n: 029-0020-74-0

FoamLogix Model 3.3 and 5.0 Installation and Operation Manual,
Hale p/n: 029-0020-68-0

The CAFSAttack smart-switches and air pressure level indicator are to be
mounted on the apparatus pump operator’s panel.

Once the major components are installed, see separate headings for pneu-
matic plumbing and electrical hookup instructions.

Plumbing - see 4.7 “Plumbing” on page 31.

Electrical - see 4.8 “Electrical” on page 38.

WARNING !

WHILE INSTALLING A CAFSATTACK SYSTEM MAKE SURE ALL SAFETY
REGULATIONS AND INSTRUCTIONS ARE FOLLOWED TO PROVIDE A SAFE
INSTALLATION. THOROUGHLY REVIEW SECTION 1 “SAFETY PRECAU-
TIONS” BEGINNING ON PAGE 7.

2.2

SMART-SWITCH CONTROLLER (SPC)

The “Smart-Switch” Panel Controller (SPC) is the primary controller for both
compressed air injection and discharge valve control. The SPC allows the
operator to inject air and control the consistency of the discharged finished
foam. (See Figure 2-2: “Smart-Switch Controller - SPC,” on page 19.)

OPEN Button, Discharge Valve

(See Figure 2-2: “Smart-Switch Controller - SPC,” on page 19.)

The OPEN button opens the water discharge valve to increase water or
foam solution (making a wetter solution). Holding the button pressed opens
the valve until the internal limit switch activates, indicating the fully OPENED
position.