Preset Calibration / Operation

54

CAFS Bottled-Air Operator/s Guide

p/n: 029-0020-85-0

6.

Begin discharging CAFS in accordance with departmental or locality
regulations. If you are satisfied with the results, continue with Step 8. to
store the setting.

7.

Use the OPEN and CLOSE buttons on the smart-switch to change the
CAFS consistency to the desired DRYNESS (press OPEN for WET-
TER; press CLOSE for DRYER consistency).

8.

Once the required consistency is achieved, press and HOLD the DRY
button for about ten (10) seconds to store (program) this new Preset 1
setting. RELEASE the button when the smart-switch flashes once.

5a Basic operation

IMPORTANT !

CLASS 1 RECOMMENDS ADDITIONAL TRAINING IN STRATEGY AND TAC-
TICS OF USING CAFS BY THE AUTHORITY HAVING JURISDICTION. THIS
MANUAL IS A SIMPLE GUIDE TO CAFSATTACK SYSTEM. ADDITIONAL CAFS
OPERATION TRAINING IS REQUIRED.

BEFORE OPERATING YOUR NEW CAFSATTACK SYSTEM, PLEASE REVIEW
THIS MANUAL AND THE FOAMLOGIX MANUAL (PROVIDED WITH THE FOAM-
LOGIX SYSTEM) IN THEIR ENTIRETY. THE OPERATOR IS RESPONSIBLE
FOR OBSERVING ALL INSTRUCTIONS, SAFETY AND SPECIFIC DEPARTMEN-
TAL OR LOCAL REGULATIONS IN HIS OR HER DAILY ROUTINE RELATED TO
THE USE OF THIS EQUIPMENT.

5A.1 STARTING CAFSATTACK

1.

Energize the apparatus to provide power to the operator’s panel.

2.

Supply water to engage and operate the pump at an appropriate dis-
charge pressure.

3.

Set the CAFSAttack ENABLE switch to the ON (I) position. Also see
Figure 2-3: “CAFSAttack Operator Control Panel” on page 21.

The background indicator lights on the smart-switch controllers illumi-
nate. (See Figure 5-1: “Smart-Switch Calibration Overview,” on page
51.)