Cafsattack operator’s control panel, Figure 4-6: typical high air pressure connections – Hale CAFS Attack User Manual

Page 32

Advertising
background image

Installer Installation

32

CAFS Air Bottle Installer/Operation Guide

p/n: 029-0020-85-0

CAFSAttack Operator’s Control Panel

Figure 4-6: Typical HIGH Air Pressure Connections

WARNING !

THE CYLINDER PRESSURE LINES OPERATE AT PRESSURES UP TO 4,500
PSI (310 BAR). ALL FITTINGS, TUBING, ETC. SHOULD BE THE FLARED
TYPE AND MUST BE RATED FOR THE MAXIMUM SYSTEM OPERATING
PRESSURE.

IF HOSE IS REQUIRED, USE 3/8” (10MM) MINIMUM TO 1/2” (13MM), WIRE
REINFORCED HOSE, SUCH AS AEROQUIP FC350-16 FOR MAXIMUM AIR
FLOW.

1. A HIGH pressure air hose line (one each) must be plumbed from each DOT

air cylinder shut-off valve connection to the CAFSAttack operator panel shut-
off valve inlet port. (See Figure 4-6: “Typical HIGH Air Pressure Connections.”)