-221 Settings conflict; turned off infinite burst to allow

immediate trigger source

An infinite burst count is only allowed when an external or bus
(software) trigger source is used.

-221 Settings conflict; infinite burst changed trigger source to

BUS

An infinite burst count is only allowed when an external or bus
(software) trigger source is used.


-221 Settings conflict; burst period increased to fit entire burst

The specified number of cycles in the BURS:NYNC command takes
priority over the burst period and the waveform generator increased
the burst period to accommodate the burst count or the waveform
frequency.


-221 Settings conflict; burst count reduced to fit entire burst

Since the burst period is currently at its maximum, the waveform
generator has adjusted the burst count to accommodate the
waveform frequency.


-221 Settings conflict; triggered burst not available for noise

Noise function is not allowed in the triggered burst mode.


-221 Settings conflict; amplitude units changed to Vpp due to

high-Z load

dBm is not available as unit when the output termination is set to
“high impedance”.


-221 Settings conflict; trigger output disabled by trigger external

When using the external trigger source, the Trig Out signal is
automatically disabled.


-221 Settings conflict; trigger output connector used by burst

gate

If you have enabled burst , and selected gated burst mode, the Trig
Out
signal is automatically disabled.