Keep the motor wires as far away as possible from the feedback, control and

communication cables.

Ensure that in normal operating conditions, the shielded wires and drain carry no current.

The only time these conductors carry current is under abnormal conditions, when electrical
equipment has become a potential shock or fire hazard while conducting external EMI
interferences directly to ground, in order to prevent them from affecting the drive. Failing
to meet this requirement can result in drive/controller/host failure.

After completing the wiring, carefully inspect all wires to ensure tightness, good solder

joints and general safety.

The Tuba has the following connectors:

Type

Function

Port on Tuba

Connector Location

8-Pin RJ-45 x 2

RS-232

COMM. 1

9-Pin D-Sub socket

Analog Input

ANALOG I/O

8-Pin RJ-45 x 2

CAN
(In/Out)

COMM. 2

15-Pin high-density
D-Sub socket

Digital Outputs

COMMITTED I/O

25-Pin D-Sub plug

Digital Inputs

GENERAL I/O

15-Pin D-Sub socket

Main Feedback

FEEDBACK A

15-Pin D-Sub plug

Auxiliary Feedback FEEDBACK B

2-Pin terminal strip
Molex

Auxiliary Power
Supply

24V

+, -

10-Pin terminal block
Molex

Mains, Motor
Power & DC Link

B1, B2, M1, M2,
M3, PE, PE, AC1,
AC2, AC3